0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PT 2X1-VF-230AC

PT 2X1-VF-230AC

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    Surge Arrestor 1-Pole Single Block Unit DIN Rail

  • 数据手册
  • 价格&库存
PT 2X1-VF-230AC 数据手册
https://www.phoenixcontact.com/gb/products/2805460 Surge protection device - PT 2X1-VF-230AC - 2805460 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Rail-mountable surge arrester for higher signal voltages. Protective circuit free of leakage current for two floating signals. Nominal voltage: 230 V AC Your advantages  Plugs can be checked with CHECKMASTER  Maximum ease of maintenance thanks to the two-piece design  Base element remains an integral part of the installation  Protective devices for use in telecommunications and signaling networks according to IEC 61643-21  Consistent plug-in signal circuit protection  Impedance-neutral disconnection of plug for test and maintenance purposes Key Commercial Data Packing unit 10 pc GTIN GTIN 4046356460989 Weight per Piece (excluding packing) 71.780 g Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 44.8 mm Width 17.5 mm Depth 51.7 mm Horizontal pitch 1 Div. Complete module height 90 mm Complete module width 17.7 mm 12/30/2019   Page 1 / 8 https://www.phoenixcontact.com/gb/products/2805460 Surge protection device - PT 2X1-VF-230AC - 2805460 Technical data Dimensions Complete module depth 65.5 mm Ambient conditions Ambient temperature (operation) -40 °C ... 80 °C Degree of protection IP20 General Housing material PA 6.6 Flammability rating according to UL 94 V-0 Color black Mounting type DIN rail: 35 mm Type DIN rail module, two-section, divisible Number of positions 2 Direction of action Line-Line & Line-Earth Ground Protective circuit IEC test classification C1 C2 C3 D1 Nominal voltage UN 230 V AC Maximum continuous voltage UC 250 V AC Rated current 6A Operating effective current IC at UC ≤ 2 µA Residual current IPE ≤ 2 µA (at UN) Nominal discharge current In (8/20) µs 3 kA Nominal discharge current In (8/20) µs (line-earth) 3 kA Pulse discharge current Iimp (10/350) µs 500 A Total discharge current Itotal (8/20) µs 8 kA Total discharge current Itotal (10/350) µs 1 kA Max. discharge current Imax (8/20) µs 8 kA Max. discharge current Imax (8/20) µs maximum (line-earth) 8 kA Nominal pulse current Ian (10/1000) µs (line-earth) 100 A Output voltage limitation at 1 kV/µs (line-earth) static ≤ 1.4 kV Residual voltage at In (line-line) ≤ 2 kV Residual voltage at In (line-earth) ≤ 1 kV Residual voltage with Ian (10/1000) µs (line-line) ≤ 1.4 kV Residual voltage with Ian (10/1000) µs (line-earth) ≤ 700 V Energy absorption 150 J Voltage protection level Up (line-line) ≤ 2.5 kV (C2 - 4 kV / 2 kA) ≤ 1.8 kV (C3 - 100 A) ≤ 2.6 kV (D1 - 500 A) 12/30/2019   Page 2 / 8 https://www.phoenixcontact.com/gb/products/2805460 Surge protection device - PT 2X1-VF-230AC - 2805460 Technical data Protective circuit Voltage protection level Up (line-earth) ≤ 1.1 kV (C1 - 500 A) ≤ 1.5 kV (C2 - 4 kV / 2 kA) ≤ 1.6 kV (C3 - 100 A) ≤ 1.8 kV (D1 - 500 A) Response time tA ≤ 100 ns Capacity (line-line) typ. 4.5 pF Capacity (line-earth) typ. 9 pF Resistance per path 0Ω Surge protection fault message optical Max. required back-up fuse 6 A (gL / gG) Impulse durability (line-earth) C2 - 4 kV / 2 kA C3 - 100 A D1 - 500 A Connection data Connection method Screw connection Connection method IN Screw terminal blocks Connection method OUT Screw terminal blocks Screw thread M3 Tightening torque 0.8 Nm Stripping length 8 mm Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section solid 0.2 mm² ... 4 mm² Conductor cross section AWG 24 ... 12 Connection, equipotential bonding Connection method Screw connection Tightening torque, min 0.8 Nm Remote indication contact Switching function N/C contact Maximum operating voltage Umax. AC 250 V AC Max. operating current Imax 1A Standards and Regulations Standards/regulations DIN EN 61643-21 Standards/specifications DIN EN 61643-21 2002 Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” 12/30/2019   Page 3 / 8 https://www.phoenixcontact.com/gb/products/2805460 Surge protection device - PT 2X1-VF-230AC - 2805460 Drawings Dimensional drawing Pictogram 12/30/2019   Page 4 / 8 https://www.phoenixcontact.com/gb/products/2805460 Surge protection device - PT 2X1-VF-230AC - 2805460 Circuit diagram * Circuit only closed when plug is inserted. Classifications eCl@ss eCl@ss 4.0 27130800 eCl@ss 4.1 27130800 eCl@ss 5.0 27130800 eCl@ss 5.1 27130800 eCl@ss 6.0 27130800 eCl@ss 7.0 27130807 eCl@ss 8.0 27130807 eCl@ss 9.0 27130807 ETIM ETIM 2.0 EC000943 ETIM 3.0 EC000943 ETIM 4.0 EC000943 ETIM 5.0 EC000943 ETIM 6.0 EC000943 ETIM 7.0 EC000943 UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 12/30/2019   Page 5 / 8 https://www.phoenixcontact.com/gb/products/2805460 Surge protection device - PT 2X1-VF-230AC - 2805460 Classifications UNSPSC UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 UNSPSC 18.0 39121620 UNSPSC 19.0 39121620 UNSPSC 20.0 39121620 UNSPSC 21.0 39121620 Approvals Approvals Approvals EAC / EAC Ex Approvals Approval details EAC      EAC-Zulassung EAC      RU CDE.A*30.B01561 Accessories Accessories Device marking Zack marker strip - ZBN 18:UNBEDRUCKT - 2809128 Zack marker strip, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5     Labeled terminal marker 12/30/2019   Page 6 / 8 https://www.phoenixcontact.com/gb/products/2805460 Surge protection device - PT 2X1-VF-230AC - 2805460 Accessories Zack Marker strip, flat - ZBF 5,LGS:FORTL.ZAHLEN - 0808671 Zack Marker strip, flat, Strip, white, labeled, printed horizontally: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 491 ... 500, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10     Zack Marker strip, flat - ZBF 5,LGS:GERADE ZAHLEN - 0810821 Zack Marker strip, flat, Strip, white, labeled, printed horizontally: consecutive numbers 2 ... 20, 22 ... 40, etc. up to 82 ... 100, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10     Zack Marker strip, flat - ZBF 5,LGS:UNGERADE ZAHLEN - 0810863 Zack Marker strip, flat, Strip, white, labeled, printed horizontally: Odd numbers 1 - 19, 21 - 39, etc. up to 81 - 99, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10     Zack Marker strip, flat - ZBF 5,QR:FORTL.ZAHLEN - 0808697 Zack Marker strip, flat, Strip, white, labeled, Printed vertically: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 91 ... 100, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10     Marker pen Marker pen - X-PEN 0,35 - 0811228 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm     Terminal marking 12/30/2019   Page 7 / 8 https://www.phoenixcontact.com/gb/products/2805460 Surge protection device - PT 2X1-VF-230AC - 2805460 Accessories Zack Marker strip, flat - ZBF 5:UNBEDRUCKT - 0808642 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.1 x 5.2 mm, Number of individual labels: 10     Zack Marker strip, flat - ZBF 5/WH-100:UNBEDRUCKT - 0808668 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10     Additional products Shield connection - SSA 3-6 - 2839295 Shield fast connection for 3 ... 6 mm cable diameter. Potential connecting cable: 200 mm, 1 mm², color: black     Shield connection - SSA 5-10 - 2839512 Shield fast connection for 5 ... 10 mm cable diameter. Potential connecting cable: 200 mm, 1 mm², color: black     Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com 12/30/2019   Page 8 / 8
PT 2X1-VF-230AC 价格&库存

很抱歉,暂时无法提供与“PT 2X1-VF-230AC”相匹配的价格&库存,您可以联系我们找货

免费人工找货